Results
- Showing results for:
- Reset all filters
Search results
-
Journal articleLord BR, El-Daou H, Sabnis BM, et al., 2016, , Knee Surgery Sports Traumatology Arthroscopy, Vol: 25, Pages: 559-568, ISSN: 1433-7347
PURPOSE: Double-bundle (DB) anterior cruciate ligament (ACL) reconstruction may offer kinematic restoration superior to anatomic single bundle (SB), but it remains technically challenging. The femoral attachment site has the most effect on ACL graft isometry, so a simplified three-socket (3S) construct which still uses two sockets to cover the femoral ACL attachment is attractive. It was hypothesised that ACL reconstruction using three- and four-socket techniques would more closely restore native knee kinematics compared to anatomic two-socket (SB) surgery. METHODS: Nine cadaveric knees were used to evaluate the kinematics of ACL-intact, ACL-deficient, anatomic SB, three-socket, and DB arthroscopic ACL reconstructions. Suspensory fixation was used, and grafts were tensioned to match the anterior draw of the intact knee at 20°. A six-degree-of-freedom robotic system measured knee laxity under 90 N anterior tibial force and rotational laxity under 5 N-m torque. Combined moments were applied to simulate the pivot-shift subluxation: 4 N-m internal rotation and 8 N-m valgus. RESULTS: Significant differences between reconstructions were not found during anterior tibial loading, apart from SB being more lax than DB at 60° flexion. All reconstructions produced comparable laxity to the intact state, apart from SB at 60°. Significant differences between reconstructions were not found at any flexion angle during tibial internal/external applied torques. Under combined loading, DB produced significantly less laxity than SB constructs apart from anterior tibial translation at 0° and internal rotation at 45°. 3S and DB were comparable to the native knee throughout. CONCLUSION: Although 3S restored laxities to a similar extent to DB, significant superiority over SB surgery was not observed. Although statistically significant differences were found between SB and DB surgery during anterior tibial and simulated pivot-shift loading, both remain
-
Journal articleDeane JA, Mcgregor A, 2016, , BMJ Open, Vol: 6, ISSN: 2044-6055
Objectives: Despite lumbar degenerative disc disease (LDDD) being significantly associatedwith non-specific low back pain and effective treatment remaining elusive, specialistmultidisciplinary clinical stakeholder opinion remains unexplored. The present studyexamines the views of such experts.Design: A reliable and valid electronic survey was designed to establish trends usingtheoretical constructs relating to current assessment and management practices. Cliniciansfrom the Society of Back Pain Research (SBPR) U.K. were invited to take part. Quantitativedata was collated and coded using Bristol On-line Surveys (BOS) software, and contentanalysis used to systematically code and categorise qualitative data.Setting: Specialist multidisciplinary spinal interest group in the U.K.Participants: 38/141 clinically active, multidisciplinary SBPR members with specialistspinal interest participated. 84% had greater than 9 years postgraduate clinical experience.Interventions: NoneOutcome Measures: Frequency distributions were used to establish general trends inquantitative data. Qualitative responses were coded and categorised in relation to each themeand percentage responses calculated.Results: LDDD symptom recurrence, in the absence of psychosocial influence, wasassociated with physical signs of joint stiffness (26%), weakness (17%), joint hypermobility(6%), while physical factors (21%) and the ability to adapt (11%) were postulated as reasonswhy some experience pain and others do not. No one management strategy was supportedexclusively or with consensus. Regarding effective modalities, there was no significantdifference between AHP and Medic responses (p= 0.1-0.9). The future of LDDD care wasexpressed in terms of improvements in patient communication (35%), patient education(38%) and treatment stratification (24%).
-
Journal articleMa S, Boughton O, Karunaratne A, et al., 2016, , Clinical Reviews in Bone and Mineral Metabolism, Vol: 14, Pages: 150-160, ISSN: 1559-0119
Bone is a complex hierarchical structure and its principal function is to resist mechanical forces and fracture. Bone strength depends not only on the quantity of bone tissue but also on the shape and hierarchical structure. The hierarchical levels are interrelated, especially the micro-architecture, collagen and mineral components; hence analysis of their speci麍c roles in bone strength and stiffness is difficult. Synchrotron imaging technologies including micro-CT and small/wide angle X-Ray scattering/diffraction are becoming increasingly popular for studying bone because the images can resolve deformations in the micro-architecture and collagen-mineral matrix under in situ mechanical loading. Synchrotron cannot be directly applied in-vivo due to the high radiation dose but will allow researchers to carry out systematic multifaceted studies of bone ex-vivo. Identifying characteristics of aging and disease will underpin future efforts to generate novel devices and interventional therapies for assessing and promoting healthy aging. With our own research work as examples, this paper introduces how synchrotron imaging technology can be used with in-situ testing in bone research.
-
Book chapterMcGregor AH, 2016, , Sports Innovation Technology and Research, Pages: 31-38
-
Journal articleNahas S, Ieong E, Logishetty K, et al., 2016, , MUSCULOSKELETAL CARE, Vol: 14, Pages: 180-184, ISSN: 1478-2189
- Cite
- Citations: 1
-
Journal articleGrice JE, Willmott H, Halewood C, et al., 2016, , Foot & Ankle Orthopaedics, Vol: 1, ISSN: 2473-0114
<jats:sec><jats:title>Category:</jats:title><jats:p> Midfoot/Forefoot </jats:p></jats:sec><jats:sec><jats:title>Introduction/Purpose:</jats:title><jats:p> Arthrodesis of the first metatarsophalangeal joint (MTPJ) is a commonly performed procedure for the treatment of hallux rigidus. A range of fixation methods have been used. Most recently, the shape-memory staple has been described. Made from an equiatomic alloy, the staple changes its shape when heated to body temperature so as to provide compression across the arthrodesis. We aimed to determine load to failure, cyclic loading and failure characteristics of different staple configurations compared to crossed screws. </jats:p></jats:sec><jats:sec><jats:title>Methods:</jats:title><jats:p> A cadaveric porcine model was used to simulate first MTPJ arthrodesis. Five forms of fixation were tested: single vertical staple; single horizontal staple; paired staples in orthogonal superior-inferior and medial-lateral configuration (0-90° to sagittal plane); paired staples in an oblique orthogonal configuration (45-135° to sagittal plane); two crossed screws. Using a materials-testing machine, specimens were loaded in dorsiflexion to simulate weight bearing. Cyclical loading was performed from 5-40N at a rate of 0.5 Hz for 1000 cycles. Plantar gapping, shear and creep were measured. Specimens were then loaded to failure in order to generate a load-displacement curve. The mechanism of failure was noted for each group. </jats:p></jats:sec><jats:sec><jats:title>Results:</jats:title><jats:p> Single staple configurations failed at very low loads. Single vertical staples failed at a mean load 15N±5N and single horizontal staples at 19N±3N. Mean failure load for paired 0-90° staples was 43N±9N which was significantly lower than the paired 45-135° staples which failed
-
Conference paperBates AV, Mcgregor AH, Alexander C, 2016, , ESMAC, Publisher: Elsevier, ISSN: 1879-2219
-
Journal articleBuckeridge EM, Weinert-Aplin RA, Bull AM, et al., 2016, , Sports Biomechanics, Vol: 15, ISSN: 1752-6116
Strength, technique, and coordination are crucial to rowing performance, but external interventions such as foot-stretcher set-up can fine-tune technique and optimise power output. For the same resultant force, raising the height of foot-stretchers on a rowing ergometer theoretically alters the orientation of the resultant force vector in favour of the horizontal component. This study modified foot-stretcher heights and examined their instantaneous effect on foot forces and rowing technique. Ten male participants rowed at four foot-stretcher heights on an ergometer that measured handle force, stroke length, and vertical and horizontal foot forces. Rowers were instrumented with motion sensors to measure ankle, knee, hip, and lumbar–pelvic kinematics. Key resultant effects of increased foot-stretcher heights included progressive reductions in horizontal foot force, stroke length, and pelvis range of motion. Raising foot-stretcher height did not increase the horizontal component of foot force as previously speculated. The reduced ability to anteriorly rotate the pelvis at the front of the stroke may be a key obstacle in gaining benefits from raised foot-stretcher heights. This study shows that small changes in athlete set-up can influence ergometer rowing technique, and rowers must individually fine-tune their foot-stretcher height to optimise power transfer through the rowing stroke on an ergometer.
-
Conference paperJin A, Cobb JP, Hansen U, et al., 2016, , WCO-IOF-ESCEO World Congress on Osteoporosis, Osteoarthritis and Musculoskeletal Diseases, Publisher: Springer Verlag (Germany), Pages: S490-S490, ISSN: 1433-2965
-
Conference paperGeraldes D, Hansen U, Jeffers J, et al., 2016,
Interference fit optimisation for small press-fitted pegs
, International Society for Technology in Arthroplasty 2015, Publisher: BRITISH EDITORIAL SOCIETY OF BONE & JOINT SURGERY, Pages: 150-150, ISSN: 2049-4416 -
Journal articleCoudrillier B, Campbell IC, Read AT, et al., 2016, , INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, Vol: 57, Pages: 2666-2677, ISSN: 0146-0404
-
Journal articleGulati V, Simpson AI, Uzoigwe C, et al., 2016, , Journal of the Royal Society of Medicine, ISSN: 1758-1095
-
Journal articleKittl C, El-Daou H, Athwal KK, et al., 2016, , American Journal of Sports Medicine, Vol: 44, Pages: NP15-NP18, ISSN: 1552-3365
-
Book chapterHalewood C, Amis AA, 2016, , Surgery of the Meniscus, Pages: 35-45
- Cite
- Citations: 2
-
Journal articleDavda K, Smyth N, Cobb JP, et al., 2016, , ACTA ORTHOPAEDICA, Vol: 87, Pages: 314-317, ISSN: 1745-3674
-
Conference paperSymes DR, Najmudin Z, Cole JM, et al., 2016, , Compact EUV & X-ray Light Sources 2016, Publisher: OSA Publishing
Extremely bright coherent femtosecond x-ray pulses are generated in compact laserdriven electron accelerators. Micro-tomography obtained with the Gemini laser indicates the usefulness of these sources in research and clinical applications.
-
Conference paperPapi E, Bo YNJ, McGregor AH, 2016,
KNEE FLEXION MEASURED WITH A FLEXIBLE WEARABLE SENSOR
, European Society of Biomechanics Conference -
Journal articleAng WW, Sabharwal S, Johannsson H, et al., 2016, , Annals of Medicine and Surgery, Vol: 7, Pages: 24-29, ISSN: 2049-0801
The National Health Service (NHS) is currently facing a financial crisis with a projected deficit of £2billion by the end of financial year 2015/16. As operating rooms (OR) are one of the costliest components in secondary care, improving theatre efficiency should be at the forefront of efforts to improve health service efficiency. The objectives of this study were to characterize the causes of trauma OR delays and to estimate the cost of this inefficiency. A 1-month prospective single-centre study in St. Mary's Hospital. Turnaround time (TT) was used as the surrogate parameter to measure theatre efficiency. Factors including patient age, ASA score and presence of surgical and anaesthetic consultant were evaluated to identify positive or negative associations with theatre delays. Inefficiency cost was calculated by multiplying the time wasted with staff capacity costs and opportunity costs, found to be £24.77/minute. The commonest causes for increased TT were delays in sending for patients (50%) and problems with patient transport to the OR (31%). 461 min of delay was observed in 12 days, equivalent to loss of £951.58/theatre/day. Non-statistically significant trends were seen between length of delays and advancing patient age, ASA score and absence of either a senior clinician or an anaesthetic consultant. Interestingly, the trend was not as strong for absence of an anaesthetic consultant. This study found delays in operating TT to represent a sizable cost, with potential efficiency savings based on TT of £347,327/theatre/year. Further study of a larger sample is warranted to better evaluate the identified trends.
-
Journal articleGill RJ, Smith DB, Raine NE, et al., 2016, , Scientific Reports, Vol: 6, ISSN: 2045-2322
The capacity to explore soft tissue structures in detail is important in understandinganimal physiology and how this determines features such as movement, behaviour and the impactof trauma on regular function. Here we use advances in micro-computed tomography (micro-CT)technology to explore the brain of an important insect pollinator and model organism, thebumblebee (Bombus terrestris). Here we present a method for accurate imaging and exploration 2of insect brains that keeps brain tissue free from trauma and in its natural stereo-geometry, andshowcase our 3D reconstructions and analyses of 19 individual brains at high resolution.Development of this protocol allows relatively rapid and cost effective brain reconstructions,making it an accessible methodology to the wider scientific community. The protocol describes thenecessary steps for sample preparation, tissue staining, micro-CT scanning and 3D reconstruction,followed by a method for image analysis using the freeware SPIERS. These image analysis methodsdescribe how to virtually extract key composite structures from the insect brain, and wedemonstrate the application and precision of this method by calculating structural volumes andinvestigating the allometric relationships between bumblebee brain structures.
-
Journal articleSabharwal S, Carter AW, Rashid A, et al., 2016, , Bone & Joint Journal, Vol: 98B, Pages: 249-259, ISSN: 2049-4394
Aims The aims of this study were to estimate the cost of surgical treatment of fractures of the proximal humerus using a micro-costing methodology, contrast this cost with the national reimbursement tariff and establish the major determinants of cost.Methods A detailed inpatient treatment pathway was constructed using semi-structured interviews with 32 members of hospital staff. Its content validity was established through a Delphi panel evaluation. Costs were calculated using time-driven activity-based costing (TDABC) and sensitivity analysis was performed to evaluate the determinants of costResults The mean cost of the different surgical treatments was estimated to be £3282. Although this represented a profit of £1138 against the national tariff, hemiarthroplasty as a treatment choice resulted in a net loss of £952. Choice of implant and theatre staffing were the largest cost drivers. Operating theatre delays of more than one hour resulted in a loss of incomeDiscussion Our findings indicate that the national tariff does not accurately represent the cost of treatment for this condition. Effective use of the operating theatre and implant discounting are likely to be more effective cost containment approaches than control of bed-day costs.Take home message: This cost analysis of fractures of the proximal humerus reinforces the limitations of the national tariff within the English National Health Service, and underlines the importance of effective use of the operating theatre, as well as appropriate implant procurement where controlling costs of treatment is concerned.
This data is extracted from the Web of Science and reproduced under a licence from Thomson Reuters. You may not copy or re-distribute this data in whole or in part without the written consent of the Science business of Thomson Reuters.